Case
Study Fourteen
Hydrogen Sulfide Reduction - Limestone Rock Quarry Application
Problem:
A seventy- year old rock quarry site was receiving numerous complaints
from local businesses concerning odors being generated by the quarry.
The quarry was producing H2S levels as high as 154 PPM and attempts had
been made in the past to mask the odors with fragrances, but the effectiveness
of the masking agents were minimal at best.
Solution:
Histosol OP-Bio was added to the 2nd retention basin located on the first
level of the quarry. The basins capacity is 25,000 gallons, and the daily
flow rate through the basin is approximately 500,000 gallons per day.
The basin was charged (shocked) with 25 gallons of Histosol OP-Bio. A
metering pump was installed and the daily application rate was set at
25 gallons per day.
Conclusion:
Within 24 hours of the initial application of the Histosol OP-Bio product
the H2S levels were reduced to 22 PPM. Complaints from local businesses
have ceased. The quarry continues to apply the product on a daily basis.
|